2022 Allen Bradley 1769-L30ER /A CompactLogix Enet Controller - eBay 0000031413 00000 n (qa230221), Data Logging and Reporting Options in FactoryTalk View Site Edition (T011), Numeric & String Input Colors & Styles in FactoryTalk View Studio (T009), Export, Edit, and Import FactoryTalk View Studio Tags (T008), Rockwell I/O and HMI Product Update (P142), Unable to load ActiveX control, Newer version required (qa230214), Strain Gauge Force Sensor Technology (P127), Snap Signal from Banner A Comprehensive IIoT Productivity Solution (P94), P+F USi-Safety Rated Ultrasonic Sensor (P87), First Look: Retroreflective Sensor with IO-Link, Pepperl+Fuchs OBR7500-R100-2EP-IO (M5E25), Can I Message a PowerFlex 525 from a ControlLogix? If the processor is going out to get the data, the troubleshooter will find the MSG instruction when doing a cross-reference. Perfect place to start. SLC 5/05 in Slot 0 with ip address of 192.168.10.204. To verify that communication is working, we can add values in the Micro820 controller tags and see if the ControlLogix tags are populated with the data. Just like with anything else, its important to know how o troubleshoot. For this example, we need a tag in the target processor named Outbox. The ControlLogix does not have the same addressing structure as the SLC 500. So we will choose CIP Data Table Read. For the purpose of this tutorial, we will be covering the communication between a MicroLogix 1100 PLC and a CompactLogix L24ER PLC. Messages 1756-PM012 Nonvolatile Memory . his answer ID describes how to create the correct path for a MSG instruction from a ControlLogix processor to another ControlLogix processor using Ethernet with two Ethernet cards (example 1756-ENBT) The controller that initiates the message instruction has the following path (separated by commas, no spaces): 1,S1,2,xxx.yyy.zzz.www,1,S2 Where: 0000003012 00000 n The same communication path will exist for both my read and write messages. View the CompactLogix 5570 Controllers product page ControlLogix Chassis and Power Supplies. Also, it is more efficient with using multi-cast communication when communicating with more than one processor. 1756 ControlLogix, 1756 GuardLogix, 1769 CompactLogix, 1769 Compact GuardLogix, 1789 . The Automation Blog, The Automation Show, The Automation Minute, The Automation Podcast, The Automation Guy, The Automation Exchange, The Automation Forums, as well as Automation Tech Tips, Automation Tech Talk, Automation Files, Automation Tutorials, Automation Exchange, Automate News, and Automation Show are trademarks of Insights In Automation all rights reserved. Keep in mind that you may increase or decrease the setpoint of the timer in order to execute the MSG more or less frequently. 0 It is one of simplest ways to make communication between ControlLogix PLC with CompactLogix PLC or between two ControlLogix or two CompactLogix. If you see an error code, go to the instruction help for the message instruction.